Where these instruments run
Six industries take most of what leaves the factory. Each has its own failure modes — fouling, corrosion, vibration, hazardous area classification, washdown — and the instrument has to be specified for the one that applies, not for the catalogue photograph.
01 — Application
Oil & gas
Separators, storage tanks, gathering lines and tank farms. The recurring requirements are hazardous-area certification, methane detection at a distance, and level instruments that keep working when the medium coats the sensor.

Leak detection on long lines
A TDLAS methane detector measures absorption along the beam instead of at a point, so a patrol can sweep a flange stack or valve station from several metres away and find the leak without entering the hazard zone.
Interface and product level in separators
Magnetostrictive transmitters give continuous 4–20 mA or RS485 over 3–5 m of stroke with no moving parts in the vessel. A magnetic flip-column gauge alongside gives a local readout that needs no power at all.
Pump protection on transfer duty
A dry-running pump destroys itself in minutes. Thermal flow switches with no moving part in the flow path hold their set-point where a paddle switch would jam on wax or scale.
02 — Application
Chemical & petrochemical
Aggressive media, coating products, foam and exothermic reactions. Wetted material and the measuring principle matter more here than accuracy class — an instrument that survives the medium beats one that is precise for a month.

Media that coats the sensor
Capacitive level transmitters tolerate build-up better than contact switches, and the microwave switch detects through the vessel wall when even a coated probe is a liability.
Corrosion on wetted parts
SUS 316L is the default across the flow, level and pressure ranges. Where the medium attacks 316L, the probe material and process connection are specified at enquiry rather than assumed.
Small skids without a PLC
Pressure controllers with four or five relay outputs trip pumps, valves and alarms directly from the keypad — no separate control system on a dosing or transfer skid.
03 — Application
Water & wastewater
Treatment works, pumping stations, reservoirs and distribution networks. Instruments here are bought in quantity, installed outdoors, and expected to run for years without attention.

Wet wells and deep reservoirs
Submersible hydrostatic transmitters convert head into 4–20 mA and are rated IP68, so the cable gland and body survive permanent immersion rather than a splash.
Pump station flow confirmation
Thermal flow switches confirm that a duty pump is actually moving water, and trip the standby when it is not — without a paddle to foul on rags and grit.
Aeration basin dissolved oxygen
The DOG-208FA electrode and DOG200 meter cover the aeration control loop, from the raw electrode to a panel-mounted instrument with relay outputs.
04 — Application
Power generation
Boiler level, steam-side pressure, turbine and switchgear monitoring. The unusual requirement is measurement in places where a metal probe or a copper conductor is itself the hazard.

Hotspots on high-voltage plant
Fluorescent fibre-optic temperature sensing runs a purely dielectric path to the measurement point and withstands 100 kV at the fibre lead — used on switchgear, busbars and transformer windings.
Boiler and feedwater level
Magnetic flip-column gauges give a local indication that cannot fail electronically, with an optional 4–20 mA transmitter on the same column for the DCS.
Steam-side pressure
Differential and gauge pressure transmitters to 40 MPa with a 40:1 turndown, in stainless housings with G1/2 or M20×1.5 connections.
05 — Application
Food & beverage
Hygienic duty where the instrument is cleaned in place, and where a crevice is a contamination risk. Smooth wetted surfaces, no threaded pockets, and materials that survive caustic washdown.

Clean-in-place washdown
Sealed stainless housings rated IP67 and IP68 survive the wash cycle, and the absence of a paddle or vane in a flow switch removes a crevice that product can collect in.
Sanitary level and temperature
PEEK and stainless level switches plus Pt100 probes in stainless sheaths, with probe length and thread made to order to suit the vessel connection.
pH and dissolved oxygen in process
The PHG-2091Pro controller and DOG200 meter bring the analytical loop into a panel with relay outputs for dosing.
06 — Application
Pharmaceutical
Repeatable batches, documented calibration, and equipment that has to be identical across every line. The purchasing driver is consistency, not the lowest unit price.

Identical commissioning across lines
The digital thermal flow switch is set with two front-panel keys and shows live velocity on an LED display, so every unit on every line trips at the same value rather than at whatever the screw position happened to be.
Traceable calibration
Each transmitter is pressure- and insulation-tested before dispatch, and the individual calibration record is supplied with the instrument.
Filling and dispensing position
The HSM41 laser displacement sensor resolves 50–400 mm on a 655 nm spot for dispensing and fill-height work, with a TOF variant reaching 2.5 m.
Working in an industry that is not listed?
The catalogue covers the common duties; the engineering team covers the rest. Send the medium, temperature, pressure and area classification and we will say what will hold.