Specifying an instrument without a sales call

Three things decide most sensor orders: the measuring principle, the output signal your panel accepts, and the environmental rating. These pages cover all three, so an enquiry can start from a shortlist rather than a blank page.

Reference · Output signals

Which output do you need?

The output is usually the first thing to fix, because it decides what the control system has to do with the measurement — and whether you need a control system at all.

Industrial sensor output signals, their typical use, and what to watch for
SignalWhen to use itWhat to watchWhere it appears
Dry contact / relaySwitching a pump, valve, alarm or interlock directly. No controller required.Relay contacts have a finite switching life; a contact rated 1 A will not start a 5 A motor without a contactor.HWS, HLS, HTS float and magnetic switches, flow switches, pressure controllers
PNP / NPNMachine control — PLC digital input, conveyor logic, OEM equipment.Sinking versus sourcing is not interchangeable. Order the type the input card expects.HSM flow switches, UB ultrasonic sensors, HSM41 laser displacement
4–20 mA (2-wire)Long cable runs into a PLC analogue card or DCS. Immune to volt-drop over distance.The loop needs a minimum supply voltage that rises with the total loop resistance.PDD pressure transmitters, HPS submersible level, TPT temperature transmitters
0–10 V / 1–5 VShort runs inside a cabinet, or into a controller with voltage inputs.Voltage signals degrade over distance and pick up noise. Keep the run short.Selected transmitters and displacement transducers
RS485 Modbus RTUMultiple instruments on one pair of wires into a PLC, gateway or SCADA.Every device needs a unique address on the bus, and the bus needs termination at both ends.HPS submersible level, TPT100, edge gateway, power meter
Wireless — 4G / LoRa / NB-IoTSites with no mains power and no cable route: pipelines, reservoirs, heating networks.Battery life depends on reporting interval and signal strength; confirm both before sizing.Wireless pressure, temperature, level and gas instruments

Scroll the table sideways to read all four columns.

Reference · Level measurement

Six level principles, and when each one fails

Level is the widest part of the catalogue because no single principle suits every tank. The column that matters is the second one — the conditions where each principle is the wrong choice.

  • Float switch

    Good for
    A discrete point — pump start/stop, high alarm. No power needed for the switch itself.
    Avoid when
    Continuous measurement. Sticky media that will not release a float.
    Level models →
  • Magnetic flip-column gauge

    Good for
    Local indication with no electronics at all, plus an optional 4–20 mA transmitter on the same column.
    Avoid when
    Media that crystallise on the column, and narrow ranges where resolution is poor.
    Level models →
  • Magnetostrictive transmitter

    Good for
    Continuous 4–20 mA or RS485 over 3–5 m with no moving parts in the vessel.
    Avoid when
    Foam and vapour that confuse the float, unless the float is specified for it.
    Level models →
  • Hydrostatic (submersible)

    Good for
    Deep wells and reservoirs. Rated IP68, so permanent immersion is fine.
    Avoid when
    Vessels under pressure, and media with varying density — head is not level.
    Level models →
  • Capacitive

    Good for
    Viscous and coating media, and aggressive chemistry where a contact probe survives better.
    Avoid when
    Build-up that changes the dielectric, unless the probe is specified for it.
    Level models →
  • Microwave through-wall

    Good for
    Foam, build-up or aggressive chemistry where even a coated probe is a liability.
    Avoid when
    Thick or metallic vessel walls between sensor and medium.
    Level models →

Reference · Environmental rating

Reading an IP code

The first digit is solids, the second is water. The catalogue ratings below are the ones that appear across the product range; a higher number is not automatically better if the installation never sees water.

Note that IP68 requires a stated depth and duration — an IP68 claim without those two numbers is not meaningful.

IP65
Dust-tight; protected against water jets from any direction.
IP67
Dust-tight; protected against temporary immersion to 1 m for 30 minutes.
IP68
Dust-tight; protected against continuous immersion at a stated depth and duration.

Documentation

Datasheets, drawings and certificates

The specification tables on every product page are the current published data. For a purchase, an installation or an import file you usually need the document underneath it — the PDF datasheet for the exact model, a dimensioned drawing, or the certificate scans. Those are issued per request rather than posted publicly, because the revision has to match the unit you are buying.

  • PDF datasheet

    The current revision for the model, in English.

  • Dimensioned drawing

    For installation clearance and connection layout.

  • Calibration / test record

    For the individual unit, where the project requires it.

  • CE / ISO / RoHS scans

    For import and tender files.

  • Material certificate

    Wetted-part material traceability on request.

  • Selection shortlist

    Two or three candidate models against your process conditions.