Ultrasonic Proximity Sensors
UB1000-18GM55 Ultrasonic Proximity Sensor
60–1000 mm, M18

UB1000-18GM55 technical data
Measurement
- Sensing range
- 60–1000 mm
- Dead zone
- 0–60 mm
- Resolution
- 0.17 mm
- Repeatability
- ±0.15 % of full scale
- Accuracy
- ±1 % with built-in temperature drift compensation
- Response time
- 52 ms
- Switching hysteresis
- ±2 mm
- Switching frequency
- 19 Hz
Electrical
- Supply voltage
- 10–30 V DC, reverse-polarity protected
- Output
- 1 switching output, NPN or PNP, NO or NC
- Input
- Synchronisation and teach-in
- No-load current
- ≤ 30 mA
- Overload protection
- 200 mA; red and green LEDs flash together
- Load impedance
- I: 0–300 Ω; U: > 1 kΩ
- Indication
- Red LED on with no target, flashes during teach-in; green LED on with target detected
Mechanical
- Barrel size
- M18 × 55 mm
- Construction
- Cylindrical
- Material
- Nickel-plated brass sleeve, plastic parts, glass-filled epoxy resin
- Connection
- 5-pin M12
- Weight
- 38 g
- Ambient temperature
- −25 to +70 °C
- Storage temperature
- −40 to +85 °C
- Ingress protection
- IP67
Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.
Request the PDF datasheet →Ultrasonic Proximity Sensors
UB1000-18GM55Ultrasonic Proximity Sensor
60–1000 mm, M18
Metre-range M18 ultrasonic sensor: 60–1000 mm, 60 mm dead zone, 0.17 mm resolution, 52 ms response. PNP/NPN switching, teach-in, IP67, 38 g.
Engineering reply · Evaluation samples available · Custom ranges built to order
- 1 m range from an M18 barrel
- 0.17 mm resolution
- Teach-in configuration
- IP67, 38 g
- Suits bin and hopper fill height
How it works
One metre of range in an 18 mm barrel is useful for bin and hopper work where the sensor mounts on the lid and has to see the product surface at low fill. Sound at these distances spreads widely, so mount away from side walls and structural steel — the 60 mm dead zone is the near limit, but the practical limit is usually reflection from surrounding surfaces.
Typical applications
- Bin and hopper fill height
- Tank level where contact is undesirable
- Large pallet detection
Not certain UB1000-18GM55 is the right unit?
Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.
Same family
Other ultrasonic instruments

Ultrasonic Proximity Sensor
20–120 mm, M12
M12 ultrasonic sensor with a 20–120 mm sensing range, 20 mm dead zone and 0.1 mm resolution. Detects clear glass, polished metal and liquid that optical sensors miss. PNP/NPN switching output, teach-in, IP67, 16 g.
View specifications
Ultrasonic Distance Sensor
20–120 mm, analogue
The analogue-output member of the M12 family: 4–20 mA, 0–10 V, RS485 Modbus and IO-Link on one sensor, with a 20–120 mm range. Use it where you need the distance value, not just a switch.
View specifications
Illustrative imageUltrasonic Proximity Sensor
30–300 mm, M18
M18 ultrasonic sensor, 30–300 mm range, 30 mm dead zone, 0.1 mm resolution, 22 ms response. PNP/NPN switching output with teach-in, IP67, 35 g. The general-purpose size for medium detection distances.
View specifications
Ultrasonic Proximity Sensor
50–500 mm, M18
M18 ultrasonic sensor with a 50–500 mm range and 50 mm dead zone. 0.15 mm resolution, 32 ms response, PNP/NPN output, teach-in, IP67. For longer approaches through fixtures and guards.
View specifications