Flow Sensors & Switches

S400 Mass Flow Controller

Closed loop, 100–200 L/min

Request a quote

S400 technical data

Flow

Flow ranges
100 L/min, 150 L/min, 200 L/min
Control range
5–100 % of full scale
Measuring range
0–100 % of full scale
Accuracy
±1.0 % FS
Linearity
±0.5 % FS
Repeatability
±0.2 % FS
Response time
2 s (T98 within ±2 % FS of set-point)
Differential pressure required
100 L/min: 0.1–0.3 MPa; 150 L/min: 0.15–0.3 MPa; 200 L/min: 0.2–0.3 MPa
Proof pressure
3 MPa
Leak rate
1×10⁻² Pa·m³/s (helium)

Electrical

Supply
±15 V DC ±5 %, 15 V at 1 MΩ
Set-point input
4–20 mA, 1–5 V DC or 0–5 V DC
Flow output
0–5 V DC (≤ 3 mA load), 4–20 mA, 1–5 V DC or 0–5 V DC
Connector
D-SUB 15, D-SUB 9

Mechanical

Valve type
Solenoid proportional, normally closed
Mounting orientation
Any
Fittings
Swagelok 3/8″ or 10 mm; VCR 1/2″
Ambient temperature
5–45 °C
Accuracy-guaranteed temperature
15–35 °C
Weight
2.8 kg

Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.

Request the PDF datasheet →

Flow Sensors & Switches

S400Mass Flow Controller

Closed loop, 100–200 L/min

Closed-loop gas flow controller combining a thermal flow sensor and a normally-closed solenoid valve in one body. Three ranges — 100, 150 and 200 L/min — with ±1 % FS accuracy, 2 s response and 5–100 % control range. Swagelok or VCR fittings, ±15 V DC supply.

Engineering reply · Evaluation samples available · Custom ranges built to order

  • True closed-loop control, not just measurement
  • Three flow ranges: 100, 150 and 200 L/min
  • ±1.0 % FS accuracy, ±0.2 % FS repeatability
  • Normally-closed valve — fails safe on loss of power
  • Mounts in any orientation

How it works

Where the HSM switches detect flow, the S400 regulates it. A thermal sensor measures the actual flow and a normally-closed solenoid valve modulates in response, so the controller holds the set-point instead of merely reporting it. Control range is 5–100 % of full scale, which means the valve still has authority at low flow rather than shutting off abruptly. Linearity is ±0.5 % FS and repeatability ±0.2 % FS, with a 2 s settling time to within ±2 % of set-point. Accuracy is specified between 15 and 35 °C; outside that band the unit still works, but the specification widens. Body is rated to 3 MPa with a helium leak rate below 1×10⁻² Pa·m³/s, and the fittings are Swagelok 3/8″ or 10 mm, or VCR 1/2″.

Ordering notes

  • Specify gas type at order — the calibration is gas-specific and cannot be transferred between media without recalibration.
  • Requires the stated differential pressure; below it the valve loses control authority at the top of the range.

Typical applications

  • Analytical instrument gas supply
  • Semiconductor and vacuum process gas lines
  • Laboratory rigs needing a repeatable flow set-point
  • Packaging and welding shielding gas control

Not certain S400 is the right unit?

Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.