Level Sensors & Transmitters
HTS22 Magnetic Level Gauge
Side-mounted

HTS22 technical data
Measurement
- Measuring range
- 200–6000 mm
- Vane resolution
- 10 mm
- Analogue output (option)
- 4–20 mA, two-wire
- Analogue resolution
- 5 mm
- Media
- Water, oil and similar liquids
Electrical (options)
- Alarm switch
- Magnetic memory switch
- Alarm contact rating
- 40 W
Mechanical
- Working pressure
- 0–10 MPa
- Medium temperature
- 80 °C / 120 °C / 180 °C / 450 °C versions
- Body / float / flange material
- SUS 304 or 316L
- Terminal box
- Aluminium alloy
- Mounting
- Flange or thread
- Ingress protection
- IP66
Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.
Request the PDF datasheet →Level Sensors & Transmitters
HTS22Magnetic Level Gauge
Side-mounted
Side-mounted direct-reading magnetic flip gauge, 200–6000 mm, 10 MPa, up to 450 °C. Flange or threaded connection, optional 4–20 mA output and magnetic memory switches. Explosion-proof and corrosion-resistant construction for hazardous and high-pressure service.
Engineering reply · Evaluation samples available · Custom ranges built to order
- Side-mounted, direct reading, no power required
- Rated to 10 MPa and 450 °C
- Suitable for flammable and explosive service
- Optional 4–20 mA transmitter and latching alarm switches
- Flange or threaded connection
How it works
The side-mounted pattern is the standard arrangement for a vertical tank with accessible side nozzles. A float in the chamber follows the liquid, its magnet flips the external bicolour vanes, and the red/white boundary is the level. Because the chamber is sealed and the vanes are outside it, the gauge suits flammable, high-pressure and high-temperature service where a glass sight glass would be a risk. The optional transmitter gives a 4–20 mA signal, and magnetic memory switches latch at set levels so an alarm stays on after the level has passed.
Typical applications
- Chemical reactors and storage tanks
- High-pressure separators
- Flammable liquid storage
- Steam and condensate vessels
Not certain HTS22 is the right unit?
Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.
Same family
Other level instruments

Magnetic Level Gauge
Top-mounted
Direct-reading magnetic flip gauge for top mounting, 200–6000 mm range, 10 MPa and up to 450 °C. Red-and-white flip column needs no power; a 4–20 mA transmitter and magnetic memory switches can be added for remote indication and alarms.
View specifications
Rod Float Level Switch
1–4 set-points
Discrete level switch with one to four magnetic reed points on a stainless guide rod. Passive dry contacts need no power supply, and the reed elements never touch the liquid. Rod diameter 9–25 mm, pressure to 6.3 MPa, temperature to 150 °C.
View specifications
Rod Float Level Switch
Extended body
The HWS20 shares the HWS10's reed-on-rod principle with a longer, heavier-duty body for deeper tanks and wider mounting spans. Same passive dry-contact output, 1–4 set-points, 6.3 MPa and 150 °C ratings.
View specifications
Illustrative imageCable Float Level Switch
SPDT, 15 A
Injection-moulded float on a flexible rubber cable, switching 15 A at 250 V AC through an SPDT contact. Suits long cable runs, multiple points on one drop, submersible pumps and media carrying granular solids. IP68, specific gravity above 0.6.
View specifications