Level Sensors & Transmitters
HWS10 Rod Float Level Switch
1–4 set-points

HWS10 technical data
Measurement
- Measuring range
- To customer specification
- Set-points
- 1–4, positions to customer drawing
- Media
- Water, oil and similar liquids
Electrical
- Contact rating
- 10 W
- Contact resistance
- Max. 0.2 Ω
- Insulation resistance
- 100 MΩ at 500 V DC
Mechanical
- Working pressure
- 0–6.3 MPa
- Medium temperature
- −20 to +150 °C
- Rod diameter
- Φ9 mm – Φ25 mm
- Rod / float / flange material
- SUS 304 or 316L
- Terminal box
- Aluminium alloy
- Mounting
- Flange or thread
- Ingress protection
- IP65
Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.
Request the PDF datasheet →Level Sensors & Transmitters
HWS10Rod Float Level Switch
1–4 set-points
Discrete level switch with one to four magnetic reed points on a stainless guide rod. Passive dry contacts need no power supply, and the reed elements never touch the liquid. Rod diameter 9–25 mm, pressure to 6.3 MPa, temperature to 150 °C.
Engineering reply · Evaluation samples available · Custom ranges built to order
- Passive dry contact — no power supply needed
- Reed elements sealed inside the rod, never wetted
- 1–4 independently positioned set-points
- Rod and float in SUS 304 or 316L
- Maintenance-free, no calibration
How it works
The HWS10 places one or more magnetic reed elements inside a stainless guide rod; a float carrying a permanent magnet rides up and down the rod and closes each reed as it passes. Because the contact is passive, the switch needs no supply — two wires are enough. The reed element is sealed inside the rod, so it never sees the medium; only stainless steel does. Up to four points can be positioned anywhere along the rod to your drawing, which makes one instrument do the job of several. Simple, with no electronics to drift and nothing to calibrate.
Typical applications
- Tank high and low level alarm
- Pump start/stop on sumps and reservoirs
- Oil level monitoring in hydraulic reservoirs
- Multi-point batching in mixing vessels
Not certain HWS10 is the right unit?
Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.
Same family
Other level instruments

Rod Float Level Switch
Extended body
The HWS20 shares the HWS10's reed-on-rod principle with a longer, heavier-duty body for deeper tanks and wider mounting spans. Same passive dry-contact output, 1–4 set-points, 6.3 MPa and 150 °C ratings.
View specifications
Illustrative imageCable Float Level Switch
SPDT, 15 A
Injection-moulded float on a flexible rubber cable, switching 15 A at 250 V AC through an SPDT contact. Suits long cable runs, multiple points on one drop, submersible pumps and media carrying granular solids. IP68, specific gravity above 0.6.
View specifications
Magnetic Level Gauge
Top-mounted
Direct-reading magnetic flip gauge for top mounting, 200–6000 mm range, 10 MPa and up to 450 °C. Red-and-white flip column needs no power; a 4–20 mA transmitter and magnetic memory switches can be added for remote indication and alarms.
View specifications
Magnetic Level Gauge
Side-mounted
Side-mounted direct-reading magnetic flip gauge, 200–6000 mm, 10 MPa, up to 450 °C. Flange or threaded connection, optional 4–20 mA output and magnetic memory switches. Explosion-proof and corrosion-resistant construction for hazardous and high-pressure service.
View specifications