Temperature Sensors & Transmitters
HSM-FOS Fluorescent Fibre-Optic Temperature System
Multi-channel, 1–32

HSM-FOS technical data
Measurement
- Measuring range
- −40 to +200 °C (up to 300 °C to order)
- Accuracy
- ±1 °C (higher accuracy on request)
- Resolution
- 0.1 °C
- Channels
- 1–32, expandable
Electrical
- Supply voltage
- 100–300 V AC
- Output
- RS485 / Modbus RTU
Mechanical
- Ambient temperature
- −20 to +65 °C
- Ambient humidity
- ≤ 95 % at 25 °C
- Fibre
- Imported quartz fibre, 5 m standard, other lengths to order
- Probe diameter
- 2.3 mm (other diameters to order)
- Probe withstand voltage
- 100 kV (40 mm withstand length, 5 min)
Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.
Request the PDF datasheet →Temperature Sensors & Transmitters
HSM-FOSFluorescent Fibre-Optic Temperature System
Multi-channel, 1–32
Complete multi-channel fibre-optic temperature system: 1–32 channels, −40 to +200 °C (300 °C on request), ±1 °C, ±0.1 °C resolution, RS485 Modbus RTU, 100–300 V AC supply, 2.3 mm probes rated for 100 kV.
Engineering reply · Evaluation samples available · Custom ranges built to order
- 1–32 channels on one instrument
- RS485 Modbus RTU — direct to SCADA
- Probes rated 100 kV, 2.3 mm diameter
- ±1 °C accuracy, 0.1 °C resolution
- Up to 300 °C on request
- 100–300 V AC wide-range supply
How it works
The system pairs a multi-channel transmitter with a set of fluorescent probes. Each channel is independent and interrogated in turn, so one instrument covers every hot spot in a transformer, a switchgear line-up or a cable trench. Output is RS485 Modbus RTU, which means the values land directly in a SCADA or protection relay without an intermediate converter. Because the probes contain no metal and carry no current, the installation does not compromise the insulation coordination of the equipment being monitored — which is the reason this technique exists at all.
Typical applications
- Transformer hot-spot monitoring across all windings
- Switchgear and GIS contact temperature
- Cable trench and joint monitoring along a route
- Arc-furnace and induction-heating equipment
Not certain HSM-FOS is the right unit?
Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.
Same family
Other temperature instruments

Fluorescent Fibre-Optic Temperature Sensor
Dielectric, HV-rated
Fluorescent-decay temperature sensing on a quartz fibre, with no electrical path to the measurement point. −40 to +200 °C (to 300 °C on request), ±1 °C, 0.1 °C resolution, USART output, immune to electromagnetic fields and rated for 100 kV at the lead.
View specifications
Fluorescent Fibre-Optic Probe
ST connector
Replacement or additional fibre probe for the fluorescent system: ST connector, quartz fibre with PTFE jacket, rare-earth sensing tip, 3 mm overall diameter, rated to 200 °C. Bend radius 13.2 cm long-term, 4.4 cm short-term.
View specifications
Illustrative imageRTD Temperature Probe
Pt100 / Pt1000
Bare Pt100 or Pt1000 probe in a stainless sheath with a standard terminal head. −200 to +600 °C, resistance signal straight out, probe length and diameter made to order. The element to specify when the transmitter lives in the panel, not on the pipe.
View specifications
Integrated Temperature Transmitter
4–20 mA, 2-wire
Pt100 probe with an integrated transmitter in the head, giving a two-wire 4–20 mA signal directly from the sensor. −200 to +600 °C, 0.1 or 0.2 accuracy class, epoxy-potted and intrinsically safe module, IP65.
View specifications