Linear Displacement Transducers
ESC Magnetostrictive Displacement Sensor
25–2500 mm, 16-bit

ESC technical data
Measurement
- Effective stroke
- 25–2500 mm, other lengths to order
- Non-linearity
- 0.05 % FS
- Resolution
- ±0.01 mm at 16-bit D/A (current output ±0.1 mm at 12-bit)
- Repeatability
- Same as resolution
- Update time
- 1 ms (stroke ≤ 1 m); 2 ms (1 m < stroke ≤ 2 m); 3 ms (stroke > 2 m)
- Magnet speed
- Unrestricted
Electrical
- Current output
- 4–20 mA or 20–4 mA (load 0–500 Ω)
- Voltage output
- 0–10 V DC or 0–5 V DC (load ≥ 10 kΩ)
- Supply voltage
- 24 V DC ±20 % or 12 V DC ±20 %
Environment and mechanical
- Operating temperature
- −40 to +75 °C
- Humidity
- 90 %, no condensation
- Shock
- 50 g / 6 ms (GB/T 2423.5)
- Vibration
- 15 g at 10–2000 Hz (GB/T 2423.10)
- Electronic head
- PP
- Rod
- PFA
- Connection
- M12 aviation connector
- Ingress protection
- IP67
Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.
Request the PDF datasheet →Linear Displacement Transducers
ESCMagnetostrictive Displacement Sensor
25–2500 mm, 16-bit
Non-contact magnetostrictive position sensor, 25–2500 mm stroke, 16-bit D/A giving ±0.01 mm resolution on the voltage output. 1 ms update to 1 m stroke, 0.05 % FS non-linearity, IP67, −40 to +75 °C.
Engineering reply · Evaluation samples available · Custom ranges built to order
- ±0.01 mm resolution (16-bit, voltage output)
- No contact, unlimited magnet speed
- Strokes 25–2500 mm
- 1 ms update up to 1 m stroke
- IP67, −40 to +75 °C
- PFA rod, PP head
How it works
The ESC is a compact non-contact sensor for strokes up to 2.5 m, with a 16-bit D/A converter that gives ±0.01 mm resolution on the voltage output. Because the magnet slides without touching the waveguide, there is no wear limit and no restriction on magnet speed. Update time scales with stroke — 1 ms up to 1 m, 2 ms to 2 m, 3 ms beyond — which is worth knowing when the stroke is long and the loop is fast. The PFA rod and PP head suit washdown and mildly aggressive environments.
Typical applications
- High-resolution position on long strokes
- Washdown machine environments
- Magnetostrictive feedback where a rod will not fit
Not certain ESC is the right unit?
Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.
Same family
Other displacement instruments

Rod-Type Linear Transducer
0.05 % linearity
Rod-type linear position transducer for direct coupling to a moving member. Strokes 50–1250 mm, 0.05 % linearity, 0.01 mm resolution, 100-million-cycle life, 4–20 mA or 0–10 V output, IP65.
View specifications
Draw-Wire Displacement Transducer
50–20 000 mm
Draw-wire position transducer measuring up to 20 m from a compact housing where a rod will not fit. 0.05 % FS repeatability, 0.25 % FS linearity, 4–20 mA or 0–10 V, stainless 316L cable, IP65.
View specifications
Magnetostrictive Displacement Transducer
Non-contact, 0.002 % FS
Non-contact magnetostrictive position transducer with 0.005 % FS non-linearity and 0.002 % FS repeatability. Strokes 50–5000 mm, 4–20 mA, 0–10 V or RS485, explosion-proof, IP67. No wiper to wear out.
View specifications
Linear Displacement Sensor
50–1000 mm, 1 ms update
Linear displacement sensor with 50–1000 mm travel, 1 ms update time on four-wire connection, 0.05 % FS non-linearity and ±0.1 mm resolution. 4–20 mA or 0–10 V, aluminium housing, 304L rod, M12 five-pin connector.
View specifications