Motion, Photoelectric & Metering
HS101-13 Tension / Compression Load Cell
5–100 kN
HS101-13 technical data
Measurement
- Range
- 5–100 kN
- Accuracy class
- 0.1 % FS
- Rated output
- 1.2–2.0 mV/V
- Zero output
- ±0.05 mV/V
- Non-linearity
- ±0.1 % FS
- Hysteresis
- ±0.1 % FS
- Repeatability
- ±0.1 % FS
- Creep (30 min)
- ±0.1 % FS
- Temperature effect on sensitivity
- ±0.1 % FS per 10 °C
- Temperature effect on zero
- ±0.1 % FS per 10 °C
- Safe overload
- 150 % FS
- Ultimate overload
- 200 % FS
Electrical
- Input resistance
- 780 ± 20 Ω
- Output resistance
- 700 ± 10 Ω
- Insulation resistance
- ≥ 5000 MΩ at 50 V DC
- Recommended excitation
- 5–10 V DC
- Maximum excitation
- 15 V DC
Mechanical
- Temperature compensation range
- −10 to +40 °C
- Operating temperature range
- −20 to +60 °C
- Cable
- Φ5.0 × 3000 mm
- Ingress protection
- IP65
Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.
Request the PDF datasheet →Motion, Photoelectric & Metering
HS101-13Tension / Compression Load Cell
5–100 kN
Strain-gauge load cell for 5–100 kN tension or compression, 0.1 % FS accuracy, 1.2–2.0 mV/V output, 150 % safe overload and 200 % ultimate. Stainless construction, IP65, 5–10 V DC excitation.
Engineering reply · Evaluation samples available · Custom ranges built to order
- 5–100 kN range
- 0.1 % FS accuracy class
- 1.2–2.0 mV/V output
- 150 % safe overload, 200 % ultimate
- Temperature compensated −10 to +40 °C
- IP65
How it works
A strain-gauge bridge bonded to a machined element: force deflects the element, the gauges change resistance, and the bridge outputs a millivolt signal proportional to load. The 0.1 % FS accuracy class and 1.2–2.0 mV/V sensitivity are the standard figures a weighing or force-control amplifier expects, so the cell drops into existing instrumentation without a special interface. Temperature compensation is applied over −10 to +40 °C, with sensitivity and zero drift both held to ±0.1 % FS per 10 °C.
Ordering notes
- Images for this model are pending — request the current datasheet for dimensional drawings.
Typical applications
- Web tension measurement
- Press and stamping force
- Crane and hoist load limiting
- Material testing rigs
Not certain HS101-13 is the right unit?
Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.
Same family
Other motion & metering instruments

Air Damper Control System
Manual / automatic
Integrated pneumatic control block for air dampers: two imported hand valves plus a vertical solenoid valve on one manifold, with automatic and manual modes that interlock so only one is active. 0.2–1.0 MPa air, DC 24/110/220 V or AC 110 V.
View specifications
Laser Displacement Sensor
50–400 mm, 4-digit
Laser displacement sensor with a 655 nm spot measuring a 50–400 mm centre distance, plus a 940 nm infrared TOF variant reaching 2.5 m or 4 m. Metal housing, LED display and keypad setup, four-digit readout. For dispensing, packaging, automotive and AGV duty.
View specifications
Incremental Encoder
2048 PPR, hollow shaft
Photoelectric incremental encoder with a Φ76 mm body, hollow shaft in Φ12, Φ20 or Φ25 mm, up to 2048 PPR. Supply 5 V DC, 5–30 V DC or 9–26 V DC, IP54 or IP65.
View specificationsCompression Load Cell
100–5000 kg
Stainless compression load cell for 100–5000 kg, 0.5 % FS accuracy, 1.0–2.0 mV/V output, 150 % safe and 200 % ultimate overload. IP65, 5–10 V DC excitation, Φ4 or Φ5 mm cable.
View specifications