Motion, Photoelectric & Metering
SBG10 Air Damper Control System
Manual / automatic

SBG10 technical data
Pneumatic
- Operating pressure
- 0.2–1.0 MPa
- Medium
- Air
- Port size
- 8 mm, 10 mm, 15 mm
- Connection
- G1/2, M20×1.5, M22×1.5
- Manifold material
- Aluminium alloy, silver
Electrical
- Supply voltage
- DC 24 V, DC 110 V, DC 220 V, AC 110 V
- Power consumption
- < 10 W
Operation
- Automatic mode
- Left valve to AUTO, right valve to 0 — left and right solenoid coils drive damper close and reverse-flush
- Manual mode
- Left valve to MANUAL — right valve selects close or reverse-flush directly
Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.
Request the PDF datasheet →Motion, Photoelectric & Metering
SBG10Air Damper Control System
Manual / automatic
Integrated pneumatic control block for air dampers: two imported hand valves plus a vertical solenoid valve on one manifold, with automatic and manual modes that interlock so only one is active. 0.2–1.0 MPa air, DC 24/110/220 V or AC 110 V.
Engineering reply · Evaluation samples available · Custom ranges built to order
- Automatic and manual modes with mechanical interlock
- Two imported hand valves plus a vertical solenoid valve on one block
- No interconnecting pipework — compact and light
- Imported solenoid with high resistance to contaminated air
- Optional pressure gauge module and filter
- Ports 8, 10 and 15 mm
How it works
A damper on a duct needs more than one actuator: it needs to open, close, and reverse-flush, under either automatic or manual control. The SBG10 puts all of that on one aluminium manifold — two imported hand valves and a vertical solenoid valve, with the mode selected by turning the left-hand valve. In automatic, the right-hand valve sits at zero and the solenoid's left and right coils drive close and reverse-flush. Switch to manual, and the right-hand valve selects close or flush directly. The two modes interlock mechanically, so an operator cannot be fighting the solenoid. A pressure gauge module and filter can be added on the same block.
Typical applications
- Duct damper actuation in ventilation systems
- Furnace and kiln air control
- Bag-filter reverse-flush sequencing
- Manual override during commissioning or maintenance
Not certain SBG10 is the right unit?
Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.
Same family
Other motion & metering instruments

Laser Displacement Sensor
50–400 mm, 4-digit
Laser displacement sensor with a 655 nm spot measuring a 50–400 mm centre distance, plus a 940 nm infrared TOF variant reaching 2.5 m or 4 m. Metal housing, LED display and keypad setup, four-digit readout. For dispensing, packaging, automotive and AGV duty.
View specifications
Incremental Encoder
2048 PPR, hollow shaft
Photoelectric incremental encoder with a Φ76 mm body, hollow shaft in Φ12, Φ20 or Φ25 mm, up to 2048 PPR. Supply 5 V DC, 5–30 V DC or 9–26 V DC, IP54 or IP65.
View specificationsTension / Compression Load Cell
5–100 kN
Strain-gauge load cell for 5–100 kN tension or compression, 0.1 % FS accuracy, 1.2–2.0 mV/V output, 150 % safe overload and 200 % ultimate. Stainless construction, IP65, 5–10 V DC excitation.
View specificationsCompression Load Cell
100–5000 kg
Stainless compression load cell for 100–5000 kg, 0.5 % FS accuracy, 1.0–2.0 mV/V output, 150 % safe and 200 % ultimate overload. IP65, 5–10 V DC excitation, Φ4 or Φ5 mm cable.
View specifications