Level Sensors & Transmitters
HPS20 Submersible Level Transmitter
Local display

HPS20 technical data
Measurement
- Range
- 0.05–300 m
- Accuracy class
- 0.1 or 0.2
- Response time
- 1.0 ms
- Temperature effect
- 0.03 % FS/°C
- Long-term stability
- 0.2 % FS/year
- Safe overload
- 5× range (ceramic-capacitive); 2× range (piezoresistive)
Electrical
- Supply voltage
- DC 24 V (12–32 V)
- Output
- 4–20 mA
- Load impedance
- 750 Ω
- Insulation resistance
- ≥ 100 MΩ at 100 V DC
Mechanical
- Medium temperature
- −20 to +80 °C
- Ambient humidity
- 0–100 % RH
- Probe material
- Stainless steel
- Ingress protection
- IP68
Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.
Request the PDF datasheet →Level Sensors & Transmitters
HPS20Submersible Level Transmitter
Local display
The HPS10 hydrostatic transmitter with a local display head, so the level can be read at the well head. 0.05–300 m, 4–20 mA, accuracy class 0.1 or 0.2, IP68 probe, condensation-resistant vent.
Engineering reply · Evaluation samples available · Custom ranges built to order
- Local display at the cable head
- Range 0.05–300 m
- Accuracy class 0.1 or 0.2
- 4–20 mA two-wire output
- IP68 submersible probe
How it works
Same hydrostatic sensing element as the HPS10, with a display in the head so the reading is visible where the cable is terminated. In practice that saves the maintenance technician from carrying a multimeter to every well to check whether the transmitter is alive, and it makes hydrostatic readings comparable with a manual dip without opening the control cabinet.
Typical applications
- Well heads without a control panel
- Reservoir monitoring where local verification is required
- Sump level with on-site reading
Not certain HPS20 is the right unit?
Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.
Same family
Other level instruments
Illustrative imageSubmersible Level Transmitter
Hydrostatic, IP68
Hydrostatic level transmitter for wells, reservoirs and sumps. Range 0.05–300 m, 4–20 mA two-wire, 0.1 or 0.2 accuracy class, ceramic-capacitive or piezoresistive sensor. Ventilated cable prevents condensation, IP68.
View specifications
Submersible Level Controller
4 relays
Submersible hydrostatic transmitter with a 24-bit A/D front end, LED display, four relay outputs and 4–20 mA / 0–10 V / 1–5 V analogue output. Range 0.5–300 m, alarm points set from the keypad, stainless and aluminium housing.
View specifications
Submersible Level / Pressure Controller
5 relays, RS485
Five relay outputs plus RS485 Modbus and selectable analogue output, in the 100 mm round case. 0.5–300 m range, dual 24 V DC / 110–220 V AC-DC supply, high-brightness dual-row LED. For pump control with remote supervision.
View specifications
Magnetic Induction Level Transmitter
Local LCD display
Reed-chain level transmitter with a local LCD head showing the level on the vessel. 0–3000 mm, 4–20 mA or 1–5 V output, 5 mm resolution, explosion-proof housing, IP67. Suits tanks where operators need a local readout as well as a control-room signal.
View specifications