Level Sensors & Transmitters
HPS2088 Submersible Level Controller
4 relays

HPS2088 technical data
Measurement
- Measuring range
- 0.5–300 m
- Sensor type
- Piezoresistive or ceramic piezoresistive
- Accuracy class
- 0.2 or 0.5
- Sampling rate
- 4 readings per second
- Display range
- −1999 to 9999
- Long-term stability
- 0.5 % FS/year
- Power supply effect
- ≤ 0.1 % FS
Electrical
- Supply voltage
- DC 24 V
- Power consumption
- ≤ 3 W
- Analogue output
- 4–20 mA / 0–10 or 20 mA / 0–5 or 1–5 V DC
- Relay outputs
- 4 pairs
- Relay rating
- 5 A at 250 V AC, 5 A at 30 V DC
- Relay life
- > 100 000 operations
- A/D conversion
- 24-bit
Mechanical
- Ambient temperature
- −20 to +70 °C
- Medium temperature
- −20 to +80 °C
- Storage temperature
- −40 to +100 °C
- Relative humidity
- 0–80 %
- Housing material
- Stainless steel + aluminium alloy
- Connection
- Flange or thread
- Ingress protection
- IP65
Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.
Request the PDF datasheet →Level Sensors & Transmitters
HPS2088Submersible Level Controller
4 relays
Submersible hydrostatic transmitter with a 24-bit A/D front end, LED display, four relay outputs and 4–20 mA / 0–10 V / 1–5 V analogue output. Range 0.5–300 m, alarm points set from the keypad, stainless and aluminium housing.
Engineering reply · Evaluation samples available · Custom ranges built to order
- 24-bit A/D conversion
- Four relay outputs with keypad-set points
- Selectable 4–20 mA, 0–10 mA, 0–10 V or 0–5 V output
- LED display, 4 readings per second
- Range 0.5–300 m
How it works
The HPS2088 puts the measurement and the control in the same head: a hydrostatic probe feeds a 24-bit A/D converter, the microcontroller linearises and displays the depth, and four relays act on your alarm points. For a pump station that otherwise needs a transmitter plus a separate level relay, that is one instrument instead of two, and one calibration instead of two that can disagree. Analogue output is selectable between 4–20 mA, 0–10 mA, 0–10 V and 0–5 V.
Typical applications
- Pump stations needing level control without a PLC
- Reservoir high and low alarm with pump start/stop
- Wet wells with duty/standby sequencing
Not certain HPS2088 is the right unit?
Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.
Same family
Other level instruments
Illustrative imageSubmersible Level Transmitter
Hydrostatic, IP68
Hydrostatic level transmitter for wells, reservoirs and sumps. Range 0.05–300 m, 4–20 mA two-wire, 0.1 or 0.2 accuracy class, ceramic-capacitive or piezoresistive sensor. Ventilated cable prevents condensation, IP68.
View specifications
Illustrative imageSubmersible Level Transmitter
Local display
The HPS10 hydrostatic transmitter with a local display head, so the level can be read at the well head. 0.05–300 m, 4–20 mA, accuracy class 0.1 or 0.2, IP68 probe, condensation-resistant vent.
View specifications
Submersible Level / Pressure Controller
5 relays, RS485
Five relay outputs plus RS485 Modbus and selectable analogue output, in the 100 mm round case. 0.5–300 m range, dual 24 V DC / 110–220 V AC-DC supply, high-brightness dual-row LED. For pump control with remote supervision.
View specifications
Magnetic Induction Level Controller
4 relay outputs
Reed-chain level transmitter with four configurable relay outputs, bright LED display and keypad-set alarm points. 0–3000 mm range, 4–20 mA or 1–5 V output, IP67. Replaces a transmitter plus separate alarm module.
View specifications