Factory-direct manufacturer · Xiamen, China · Exporting worldwide

Level Sensors & Transmitters

HPS2088 Submersible Level Controller

4 relays

Request a quote

HPS2088 technical data

Measurement

Measuring range
0.5–300 m
Sensor type
Piezoresistive or ceramic piezoresistive
Accuracy class
0.2 or 0.5
Sampling rate
4 readings per second
Display range
−1999 to 9999
Long-term stability
0.5 % FS/year
Power supply effect
≤ 0.1 % FS

Electrical

Supply voltage
DC 24 V
Power consumption
≤ 3 W
Analogue output
4–20 mA / 0–10 or 20 mA / 0–5 or 1–5 V DC
Relay outputs
4 pairs
Relay rating
5 A at 250 V AC, 5 A at 30 V DC
Relay life
> 100 000 operations
A/D conversion
24-bit

Mechanical

Ambient temperature
−20 to +70 °C
Medium temperature
−20 to +80 °C
Storage temperature
−40 to +100 °C
Relative humidity
0–80 %
Housing material
Stainless steel + aluminium alloy
Connection
Flange or thread
Ingress protection
IP65

Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.

Request the PDF datasheet →

Level Sensors & Transmitters

HPS2088Submersible Level Controller

4 relays

Submersible hydrostatic transmitter with a 24-bit A/D front end, LED display, four relay outputs and 4–20 mA / 0–10 V / 1–5 V analogue output. Range 0.5–300 m, alarm points set from the keypad, stainless and aluminium housing.

Engineering reply · Evaluation samples available · Custom ranges built to order

  • 24-bit A/D conversion
  • Four relay outputs with keypad-set points
  • Selectable 4–20 mA, 0–10 mA, 0–10 V or 0–5 V output
  • LED display, 4 readings per second
  • Range 0.5–300 m

How it works

The HPS2088 puts the measurement and the control in the same head: a hydrostatic probe feeds a 24-bit A/D converter, the microcontroller linearises and displays the depth, and four relays act on your alarm points. For a pump station that otherwise needs a transmitter plus a separate level relay, that is one instrument instead of two, and one calibration instead of two that can disagree. Analogue output is selectable between 4–20 mA, 0–10 mA, 0–10 V and 0–5 V.

Typical applications

  • Pump stations needing level control without a PLC
  • Reservoir high and low alarm with pump start/stop
  • Wet wells with duty/standby sequencing