HWT2088 technical data

Measurement

Range
0–3000 mm
Resolution
5 mm
Output
4–20 mA or 1–5 V
Alarm outputs
4 relays
Load impedance
750 Ω

Electrical

Supply voltage
DC 24 V (12–36 V)
Power consumption
≤ 2 W

Mechanical

Working temperature
−10 to +100 °C
Working pressure
0–1 MPa, or to customer specification
Guide tube diameter
Φ9 – Φ25 mm
Tube material
Stainless steel 316L / 304
Housing material
Aluminium alloy
Connection
Flange or thread
Ingress protection
IP67

Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.

Request the PDF datasheet →

Level Sensors & Transmitters

HWT2088Magnetic Induction Level Controller

4 relay outputs

Reed-chain level transmitter with four configurable relay outputs, bright LED display and keypad-set alarm points. 0–3000 mm range, 4–20 mA or 1–5 V output, IP67. Replaces a transmitter plus separate alarm module.

Engineering reply · Evaluation samples available · Custom ranges built to order

  • Four relay outputs with keypad-set alarm points
  • Bright LED display readable in daylight
  • 4–20 mA or 1–5 V analogue output in parallel
  • Explosion-proof housing
  • Settings changed without opening the housing

How it works

The HWT2088 adds a controller to the reed-chain transmitter: four relays, each with an alarm point set from the front keypad, alongside the standard analogue output. That means a single instrument can start and stop a pump, raise high and low alarms, and still feed a 4–20 mA signal to the control room, without a separate trip amplifier. The LED display is readable in daylight, and the settings are changed by key rather than by internal jumpers, so a change of duty does not need the housing opened.

Typical applications

  • Pump control with high and low cut-outs from one probe
  • Tank farms without a dedicated PLC
  • Chemical dosing tank level interlock

Not certain HWT2088 is the right unit?

Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.