Factory-direct manufacturer · Xiamen, China · Exporting worldwide

Level Sensors & Transmitters

HWT10 Magnetic Induction Level Transmitter

Continuous, 4–20 mA

Request a quote

HWT10 technical data

Measurement

Range
0–3000 mm
Resolution
5 mm
Output
4–20 mA DC
Load impedance
750 Ω

Electrical

Supply voltage
DC 24 V (12–36 V)
Power consumption
≤ 0.72 W

Mechanical

Working temperature
−10 to +100 °C
Working pressure
0–1 MPa, or to customer specification
Guide tube diameter
Φ9 – Φ25 mm
Tube material
Stainless steel 316L / 304
Housing material
Aluminium alloy
Connection
Flange or thread
Ingress protection
IP67

Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.

Request the PDF datasheet →

Level Sensors & Transmitters

HWT10Magnetic Induction Level Transmitter

Continuous, 4–20 mA

Continuous level transmitter using a chain of magnetic reed modules inside a stainless guide tube. Range to 3000 mm, 4–20 mA two-wire output, 5 mm resolution, 750 Ω load. Explosion-proof aluminium housing, IP67, flange or threaded mounting.

Engineering reply · Evaluation samples available · Custom ranges built to order

  • Continuous 4–20 mA output, two-wire
  • Range up to 3000 mm, 5 mm resolution
  • Explosion-proof aluminium housing
  • All-stainless wetted parts, 316L or 304
  • Unaffected by foam, vapour or dielectric change

How it works

Instead of separate switch points, the HWT10 fills the guide tube with a series of reed modules and precision resistors. A magnetic float closes the reeds at its own height, and the resulting resistance is converted to a continuous 4–20 mA signal proportional to level. The electronics live inside an explosion-proof aluminium housing, and the tube and float are 316L or 304 stainless, so the instrument suits fuel and chemical tanks as well as water. There is no capacitive drift and no ultrasonic dead zone; the output follows the float directly.

Typical applications

  • Fuel and lube oil tank gauging
  • Chemical storage with flammable contents
  • Water and wastewater level control
  • Tanks where ultrasonic or radar would be defeated by foam

Not certain HWT10 is the right unit?

Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.

Same family

Other level instruments