HWT20 technical data
Measurement
- Range
- 0–3000 mm
- Resolution
- 5 mm
- Output
- 4–20 mA or 1–5 V
- Load impedance
- 750 Ω
Electrical
- Supply voltage
- DC 24 V (12–36 V)
- Power consumption
- ≤ 0.72 W
Mechanical
- Working temperature
- −10 to +100 °C
- Working pressure
- 0–1 MPa, or to customer specification
- Guide tube diameter
- Φ9 – Φ25 mm
- Tube material
- Stainless steel 316L / 304
- Housing material
- Aluminium alloy
- Connection
- Flange or thread
- Ingress protection
- IP67
Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.
Request the PDF datasheet →Level Sensors & Transmitters
HWT20Magnetic Induction Level Transmitter
Local LCD display
Reed-chain level transmitter with a local LCD head showing the level on the vessel. 0–3000 mm, 4–20 mA or 1–5 V output, 5 mm resolution, explosion-proof housing, IP67. Suits tanks where operators need a local readout as well as a control-room signal.
Engineering reply · Evaluation samples available · Custom ranges built to order
- Local LCD display plus remote signal
- Continuous output, 4–20 mA or 1–5 V
- Explosion-proof housing
- Range up to 3000 mm, 5 mm resolution
- No drift, no dead zone
How it works
The HWT20 is the HWT10 with an LCD head. The measuring element is the same reed-and-resistor chain, so the output follows the float with no drift and no dead zone, but the technician standing at the tank can read the level directly instead of trusting that the signal is right. Output is 4–20 mA or 1–5 V, both with 750 Ω load capability, and the aluminium housing is explosion-proof for flammable service.
Typical applications
- Tanks where operators take manual dips
- Fuel depots with local and central indication
- Water treatment chemical tanks
Not certain HWT20 is the right unit?
Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.
Same family
Other level instruments

Magnetic Induction Level Transmitter
Continuous, 4–20 mA
Continuous level transmitter using a chain of magnetic reed modules inside a stainless guide tube. Range to 3000 mm, 4–20 mA two-wire output, 5 mm resolution, 750 Ω load. Explosion-proof aluminium housing, IP67, flange or threaded mounting.
View specifications
Magnetic Induction Level Controller
4 relay outputs
Reed-chain level transmitter with four configurable relay outputs, bright LED display and keypad-set alarm points. 0–3000 mm range, 4–20 mA or 1–5 V output, IP67. Replaces a transmitter plus separate alarm module.
View specifications
Magnetic Induction Level Controller
5 relays, dual supply
Five relay outputs plus 4–20 mA or 1–5 V, keypad-configured, with dual 24 V DC / 220 V AC supply so it can be wired straight into an existing panel. LED display, IP67, range to 3000 mm.
View specifications
Illustrative imageSubmersible Level Transmitter
Local display
The HPS10 hydrostatic transmitter with a local display head, so the level can be read at the well head. 0.05–300 m, 4–20 mA, accuracy class 0.1 or 0.2, IP68 probe, condensation-resistant vent.
View specifications