Pressure Transmitters & Controllers
PDD1020 Differential Pressure Transmitter
Compact stainless body

PDD1020 technical data
Measurement
- Range
- −100 kPa to +200 kPa (bi-directional)
- Accuracy class
- 0.2 or 0.5
- Non-linearity
- 0.2
- Hysteresis
- ≤ 0.01 % of span
- Long-term stability
- 0.15 % FS/year
- Overload capability
- 2–3× span
- Temperature effect
- 0.15 %/K
Electrical
- Supply voltage
- DC 24 V (12–36 V)
- Output
- Two-wire 4–20 mA; three-wire 1–5 V
- Load impedance
- 750 Ω
- Insulation resistance
- ≥ 100 MΩ at 100 V DC
Mechanical
- Medium
- Gases compatible with 316L
- Housing material
- Stainless steel
- Process connection
- G1/2″, M20×1.5 or to order
- Ambient temperature
- −30 to +70 °C
- Medium temperature
- −30 to +80 °C
- Storage temperature
- −40 to +85 °C
- Ingress protection
- IP65
Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.
Request the PDF datasheet →Pressure Transmitters & Controllers
PDD1020Differential Pressure Transmitter
Compact stainless body
Compact differential pressure transmitter, −100 kPa to 200 kPa, in a small stainless body for tight installation space. Two-wire 4–20 mA or three-wire 1–5 V, 0.2 accuracy class, G1/2 or M20×1.5, IP65.
Engineering reply · Evaluation samples available · Custom ranges built to order
- Compact stainless body for tight spaces
- Same range and accuracy as the PDD2088
- Two-wire 4–20 mA or three-wire 1–5 V
- 0.2 accuracy class, 0.15 % FS/year stability
- G1/2 or M20×1.5
How it works
The PDD1020 does the same job as the PDD2088 in a smaller stainless housing, for panels and skids where the 2088 head will not fit or where the extra volume is simply not needed. The measuring range and accuracy are identical, as are the electrical options, so a plant can mix the two without introducing a second set of spares, wiring conventions or configuration instructions.
Typical applications
- Compact skids and packaged plant
- Panel-mounted differential pressure
- Instrument air and gas train monitoring
Not certain PDD1020 is the right unit?
Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.
Same family
Other pressure instruments

Differential Pressure Transmitter
0.2 class, 40:1 turndown
Differential pressure transmitter covering 0–0.2 kPa to 40 MPa with a 40:1 turndown and 0.2 accuracy class. Two-wire 4–20 mA, 750 Ω load, stainless housing, IP65. Built on a δ-cell capacitive sensor with a 0.10 mm measuring diaphragm.
View specifications
Differential Pressure Transmitter
Bidirectional, 2088 housing
Bidirectional differential pressure transmitter spanning −100 kPa to 200 kPa, in the standard 2088 housing with a liquid-crystal head. Two-wire 4–20 mA or three-wire 1–5 V, 0.2 accuracy class, stainless body, IP65.
View specifications
Pressure Transmitter Controller
4 relays
Pressure transmitter with a 24-bit A/D, LED display, four relay outputs and selectable analogue output. −0.1 to 60 MPa, 0.2 accuracy class, diffusion-silicon, ceramic piezoresistive or ceramic capacitive sensor, stainless and aluminium housing.
View specifications
Pressure Transmitter Controller
5 relays, 150 mm case
Five relay outputs in a Φ150 mm gauge case, with dual 24 V DC / 220 V AC supply so it replaces a mechanical gauge in situ. −0.1 to 60 MPa, 0.2 accuracy class, high-brightness LED display, selectable analogue output.
View specifications